SECTION 8 - DIAGNOSTIC TROUBLE CODES
3121222 – JLG Lift – 8-5
8.4 DTC CHECK TABLES
0-0 Help Comments
DTC FAULT MESSAGE DESCRIPTION CHECK
001 EVERYTHING OK The normal help message in platform
mode. Displays on the analyzer only.
002 GROUND MODE OK The normal help message in ground
mode. Displays on the analyzer only.
003 ALARM SOUNDING - TILTED
& ABOVE ELEVATION
Control system senses that the platform
is elevated and the vehicle is tilted, and
the machine not configured to cutout.
Check that the machine is tilted. If so, lower the platform and
reposition the machine to a level surface.
Fully stow the platform.
The tilt sensor is part of the ground control box. Check that the
ground control box is secured to the machine.
Check that the pothole protection switches are securely mounted.
Check that the elevation angle sensor is securely mounted.
Check the ANALYZER -> MACHINE SETUP -> MARKET configu-
ration.
If MARKET is set to CE, ensure ANALYZER -> MACHINE SETUP -
> TILT CUTOUT parameter is set as desired.
Backprobing ground board J1-18 should show about 0 volts.
Backprobing ground board J1-10 should show about 0 volts.
Check pothole protection switch adjustment.
Calibrate the elevation sensor, see Section 5.5.
Calibrate the tilt sensor, see Section 5.2.
004 DRIVING AT CUTBACK -
ABOVE ELEVATION
The platform is elevated and the machine
is driving.
Fully stow the platform.
Check that the elevation angle sensor is securely mounted.
Check that the pothole protection switches are securely mounted.
Check the lift/drive switch.
Backprobing ground board J1-18 should show about 0 volts.
Backprobing ground board J1-10 should show about 0 volts.
Check function of elevation angle sensor. ANALYZER -> DIAG-
NOSTICS -> ELEV SENSOR -> ZEROED should be about 0V
when stowed and about 0.15V at cutback.
005 DRIVE & LIFT UP PRE-
VENTED - TILTED & ELE-
VATED
Driving is not possible since the platform
is elevated and the chassis is not level.
Check that the machine is tilted. If so, lower the platform and
reposition the machine to a level surface.
Fully stow the platform.
The tilt sensor is part of the ground control box. Check that the
ground control box is secured to the machine.
Check that the pothole protection switches are securely mounted.
Check that the elevation angle sensor is securely mounted.
Check the ANALYZER -> MACHINE SETUP -> MARKET configu-
ration.
If MARKET is set to CE, ensure ANALYZER -> MACHINE SETUP -
> TILT CUTOUT parameter is set as desired.
Check pothole protection switch adjustment.
Backprobing ground board J1-18 should show about 0 volts.
Backprobing ground board J1-10 should show about 0 volts.
Calibrate the elevation sensor, see Section 5.5.
Calibrate the tilt sensor, see Section 5.2.