Jlg E300 Operator Manual Manuel d'utilisateur Page 38

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 100
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 37
SECTION 3 - MACHINE CONTROLS AND INDICATORS
3-6 – JLG Lift – 3121214
WHEN THE MACHINE IS SHUT DOWN THE MASTER/EMERGENCY STOP
SWITCH MUST BE POSITIONED TO THE OFF POSITION TO PREVENT
DRAINING THE BATTERIES.
10. Power/Emergency Stop Switch.
A two-position red mushroom shaped switch furnishes
power to PLATFORM/GROUND SELECT switch when
pulled out (on). When pushed in (off), power is shut off
to the PLATFORM/GROUND SELECT switch.
11. Battery Indicator and Hourmeter
The battery indicator registers the present charge of the
batteries. The hourmeter registers the amount of
machine operating time, up to 9,999.9 hours, and can-
not be reset.
12. Control Station Selector
Supplies power to the platform control console when
positioned to the PLATFORM. With the switch in
GROUND position, power is shut off to the platform con-
trol console, and only the controls on the ground control
panel are operable.
NOTE: When the Platform/Ground Select Switch is in the center
position, power is shut off to the controls at both operat-
ing stations. Remove the key to prevent the controls from
being actuated. The key is removable in the platform posi-
tion on CE machines. The key must be available to ground
personnel in the event of an emergency.
13. Platform Overload (If equipped)
Indicates the platform has been overloaded.
14. Function Enable
If equipped, the enable switch must be held "DOWN" to
enable all boom controls when the engine is running.
Vue de la page 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 99 100

Commentaires sur ces manuels

Pas de commentaire