Jlg 723A Operator Manual Manuel d'utilisateur Page 53

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 172
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 52
Section 3 - Controls and Indicators
3-1531200567
S/N 1160005989 & After including 1160005189, 1160005314 & 1160005414
The LSI (7) provides visual and audible indication of forward stability limitations
when machine is static on firm, level surface.
Green LED (8) will illuminate when LSI power is on.
When approaching forward stability limitations LEDs progressively illuminate,
green (9), then orange (10) and finally red (11).
If the red LED illuminates the warning buzzer also sounds.
The LSI has two modes:
Active Mode
As the telehandler reaches forward stability limitations and the red LED (11)
illuminates, the automatic function cut-out is activated. All boom, frame level
and outrigger functions are disabled except for boom retract (CE & AUS)
and boom lift (CE). Retract boom to re-enable functions.
In some instances the LSI system may slow down or stop boom functions if
operated close to forward stability limitations. When LEDs begin to flash,
certain functions can not be operated. Retract boom and/or return the
joystick to neutral position for a short period to allow system to reset and
LEDs to stop flashing before proceeding with operation.
Passive Mode
The orange LED (13) illuminates when either of the following occurs:
The boom is fully retracted.
The park brake is not applied and transmission control lever is in the
forward or reverse position.
When approaching forward stability limitations, visual and audible indication
is provided and the automatic function cut-out and/or slow down feature is
disabled.
OAH2092
12
9
10
8
11
7
13
Vue de la page 52