SECTION 3 - MACHINE CONTROLS AND INDICATORS
3121678 – JLG Lift – 3-15
Platform Control Indicator Panel
(See Figure 3-3., Platform Control Indicator Panel)
1. Level System Fault Indicator
Indicates a fault in the electronic leveling sys-
tem. The fault indicator will flash and an alarm
sound. All functions will default to creep if the
boom is extended more than 20 inches (51 cm) or elevated
above horizontal.
IF THE LEVEL SYSTEM FAULT INDICATOR IS ILLUMINATED, SHUT DOWN THE
MACHINE, RECYCLE THE EMERGENCY STOP, AND RESTART THE MACHINE. IF THE
FAULT PERSISTS, RETURN THE PLATFORM TO THE STOWED POSITION, USING MAN-
UAL LEVELING AS REQUIRED, AND HAVE LEVELING SYSTEM REPAIRED.
2. AC Generator (If Equipped)
Indicates the generator is in operation.
3. Platform Overload (If equipped)
Indicates the platform has been overloaded.
4. Capacity Indicator
Indicates the maximum platform capacity for
the current position of the platform. Restricted
capacities are permitted at restricted platform
positions (shorter boom lengths and higher
boom angles).
NOTE: Refer to the capacity decals on the machine for restricted and
unrestricted platform capacities.